Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Arq. bras. oftalmol ; 87(5): e2022, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1527854

ABSTRACT

ABSTRACT Purpose: This study aimed to compare an teriorchamber parameters acquired by a swept-source anteriorsegment optical coherence tomography before and after laser peripheral iridotomy. Methods: This study prospectively evaluated 14 patients with primary-angle closure and six patients with primary-angle closure glaucoma. Gonioscopy and anterior-segment optical coherence tomography using the DRI OCT Triton® were performed before and after laser peripheral iridotomy. Anterior-segment optical coherence tomography parameters were studied using scleral spur as reference: angle opening distance at 250, 500, and 750 µm, trabecular-iris space at 500 µm, trabecular-iris angle, trabecular-iris contact length, and iris curvature. Results: Anterior-segment optical coherence tomography identified 61% of the patients with two or more quadrants closed. Gonioscopy identified more closed angles than anterior-segment optical coherence tomography before laser peripheral iridotomy. In angle parameters, only the angle opening distance of 250 µm at the nasal quadrant was not significantly increased after laser peripheral iridotomy. The iris curvature and trabecular-iris contact length showed a significant reduction induced by the laser procedure. Even in eyes in which gonioscopy did not identify angular widening after laser peripheral iridotomy (n=7), the angle opening distance of 750 µm increased (nasal, 0.15 ± 0.10 mm to 0.27 ± 0.16 mm, p=0.01; temporal, 0.14 ± 0.11 mm to 0.25 ± 0.12 mm, p=0.001) and the iris curvature decreased (nasal, 0.25 ± 0.04 mm vs. 0.11 ± 0.07 mm, p=0.02; temporal, 0.25 ± 0.07 mm vs. 0.14 ± 0.08 mm, p=0.007). Conclusions: Anterior-chamber changes induced by laser peripheral iridotomy could be quantitatively evaluated and documented by DRI OCT Triton®


RESUMO Objetivo: Comparar os parâmetros de câmara anterior obtidos através da tomografia de coerência óptica de segmento anterior antes e após a iridectomia periférica a laser. Métodos: Quatorze pacientes com fechamento angular primário e seis com glaucoma primário de ângulo fechado foram prospectivamente avaliados neste estudo. Gonioscopia e tomografia de coerência óptica de segmento anterior com DRI OCT Triton® foram realizadas antes e após a iridectomia periférica a laser. Os seguintes parâmetros de tomografia de coerência óptica de segmento anterior, baseados na localização do esporão escleral, foram avaliados: ângulo de abertura angular a 250 µm, 500 µm e 750 µm, área do espaço entre a íris e o trabeculado a 500 µm, ângulo entre a íris e o trabeculado, extensão do contato entre a íris e o trabeculado e curvatura da íris. Resultados: A tomografia de coerência óptica de segmento anterior identificou 61% dos indivíduos com dois ou mais quadrantes fechados. A gonioscopia identificou mais quadrantes com ângulo fechado do que tomografia de coerência óptica de segmento anterior antes da iridectomia periférica a laser. Quanto aos parâmetros angulares, apenas ângulo de abertura angular a 250 µm no quadrante nasal não aumentou significativamente após a iridectomia periférica a laser. A curvatura da íris e a extensão do contato entre a íris e o trabeculado apresentaram redução significativa induzida pelo procedimento a laser. Mesmo nos olhos em que a gonioscopia não identificou aumento da amplitude angular após iridectomia periférica a laser (n=7), ângulo de abertura angular a 750 µm aumentou (nasal: 0,15 ± 0,10 mm para 0,27 ± 0,16 mm, p=0,01; temporal: 0,14 ± 0,11 mm para 0,25 ± 0,12 mm, p=0,001), e ICURVE diminuiu (nasal: 0,25 ± 0,04 mm vs. 0,11 ± 0,07 mm, p=0,02; temporal: 0,25 ± 0,07 mm vs. 0,14 ± 0,08 mm, p=0,007). Conclusões: As alterações na câmara anterior induzidas pelo iridectomia periférica a laser puderam ser avaliadas quantitativamente e documentadas pelo DRI OCT Triton®.

2.
Rev. bras. oftalmol ; 81: e0104, 2022. graf
Article in Portuguese | LILACS | ID: biblio-1407679

ABSTRACT

RESUMO O óleo de silicone é um importante tampão utilizado na retinopexia cirúrgica de casos graves de descolamento de retina. O aumento da pressão intraocular e o desenvolvimento de glaucoma secundário são frequentes complicações da sua utilização. A depender do período de aparecimento, diversos mecanismos justificam a ocorrência de tais complicações. Compreender os fatores de riscos e a patogênese do aumento da pressão intraocular associada a aplicação de óleo de silicone em cirurgia retiniana ajuda a orientar o tratamento adequado para cada paciente. O objetivo deste artigo é revisar a literatura sobre a patogenia, a incidência, os fatores de risco e o tratamento desta condição clínica.


ABSTRACT Silicone oil has been an important intraocular tamponade in retinopexy in cases of complicated retinal detachment surgery. The increase of intraocular pressure and development of secondary glaucoma are a known complication of its use. A variety of mechanisms have been proposed for the pathogenesis, depending on the onset. This article aims to review the literature about pathogenesis, the incidence and risk factors, as well as the treatment of this pathology.


Subject(s)
Humans , Silicone Oils/adverse effects , Silicone Oils/therapeutic use , Retinal Detachment/therapy , Glaucoma/chemically induced , Ocular Hypertension/chemically induced , Intraocular Pressure/drug effects , Postoperative Complications , Trabecular Meshwork , Retinal Detachment/surgery , Trabeculectomy , Glaucoma/surgery , Risk Factors , Glaucoma Drainage Implants , Laser Therapy , Therapeutic Occlusion/methods , Light Coagulation
3.
Arq. bras. oftalmol ; 80(5): 313-316, Sept.-Oct. 2017. tab
Article in English | LILACS | ID: biblio-888146

ABSTRACT

ABSTRACT Objective: The aim of this study was to determine the central corneal thickness (CCT) and intraocular pressure (IOP) in full-term newborns and to correlate these values with the following variables: weight, sex, and post-conception age (PCA). Methods: IOP and CCT were determined in 52 full-term newborns with a mean gestational age of 39.43 ± 1.03 weeks and a mean birth weight of 3,273 ± 558 g. The mean age of the neonates at the time of taking the measurements was 1.15 ± 1.38 days after birth. IOP was determined with a Tono-Pen, and CCT was determined using a handheld ultrasound pachymeter. Results: The mean overall IOP was 14.0 ± 2.91 mmHg, and the mean IOP in male and female newborns was 13.77 ± 2.88 mmHg and 14.32 ± 3.05 mmHg, respectively. The mean overall CCT was 605.87 ± 62.98 µm, and the mean CCT in male and female newborns was 626.70 ± 67.46 µm and 577.45 ± 45.50 µm, respectively; the mean CCT was higher in male newborns than in female newborns. PCA was negatively associated with CCT, IOP, and weight; however, only the correlation with CCT was statistically significant. Comparisons between the sexes showed significant differences for two variables: weight and CCT. Conclusions: No relationship was found between CCT and IOP; however, we found a positive association between weight and CCT.


RESUMO Objetivo: O objetivo deste estudo foi avaliar a espessura central da córnea (ECC) e a pressão intraocular (PIO) em recém-nascidos (RN) a termo, correlacionando seus valores entre as variáveis peso, sexo e idade pós-concepção (PCA). Métodos: A pressão intraocular e a espessura central da córnea foram determi­nadas em 52 recém-nascidos a termo com idade gestacional média de 39,43 ± 1,03 semanas, peso médio de nascimento de 3.273 ± 558 g. A média de idade durante as medições após o nascimento foi 1,15 ± 1,38 dias. A pressão intraocular foi determinada com Tono-pen. A espessura central da córnea foi determinada com paquímetro ultrassônico portátil. Resultados: A pressão intraocular média foi de 14,0 ± 2,91 mmHg em ambos os sexos, de 13,77 ± 2,88 mmHg nos recém-nascidos do sexo masculino e 14,32 ± 3,05 mmHg nos recém-nascidos do sexo feminino. A espessura central da córnea média foi de 605,87 ± 62,98 µm em ambos os sexos; de 626,70 ± 67,46 µm recém-nascidos do sexo masculino e de 577,45 ± 45,50 µm nos recém-nascidos do sexo feminino. A maior média da espessura da córnea foi no sexo masculino. A variável idade pós-concepção teve uma relação decrescente com espessura central da córnea, pressão intraocular e peso, porém, a correlação só foi significante com a espessura central da córnea. Na comparação entre os sexos houve diferenças significativas para duas variáveis: peso e espessura central da córnea. Conclusões: Não houve relação entre a espessura central da córnea e a pressão intraocular neste estudo, entretanto verificou-se que existe uma relação de aumento de peso com a espessura central da córnea.


Subject(s)
Humans , Male , Female , Infant, Newborn , Cornea/anatomy & histology , Term Birth , Corneal Pachymetry , Intraocular Pressure/physiology , Time Factors , Tonometry, Ocular , Birth Weight , Sex Factors , Glaucoma/etiology , Gestational Age , Statistics, Nonparametric
4.
Arq. bras. oftalmol ; 79(4): 270-276, July-Aug. 2016.
Article in English | LILACS | ID: lil-794587

ABSTRACT

ABSTRACT Normal-tension glaucoma (NTG) is a progressive optic neuropathy with intraocular pressure (IOP) within the statistically normal range (≤21 mmHg). The prevalence of NTG varies widely among different population studies, being the most prevalent open-angle glaucoma subtype in some reports. The etiology of NTG possibly is multifactorial and still not well defined. Alternative treatments have been proposed based on pathogenesis details. However, in clinical practice, adequate reduction of IOP remains the keystone of managing patients with NTG. We review the pathogenesis of NTG and the available therapies for this optic neuropathy.


RESUMO O glaucoma de pressão normal (GPN) é uma neuropatia óptica progressiva que cursa com a pressão intraocular (PIO) dentro da faixa de normalidade (≤21 mmHg). A prevalência do glaucoma de pressão normal varia entre os estudos populacionais, sendo em alguns o principal subtipo de glaucoma primário de ângulo aberto. A etiologia do glaucoma de pressão normal possivelmente é multifatorial e ainda não foi totalmente esclarecida. Tratamentos alternativos baseados nos diferentes detalhes da patogenia foram recentemente propostos. Entretanto, na prática clínica, a redução adequada da pressão intraocular continua sendo a base do tratamento do glaucoma de pressão normal. O objetivo deste artigo é revisar a patogênese do glaucoma de pressão normal e as formas de terapia disponíveis.


Subject(s)
Humans , Low Tension Glaucoma/physiopathology , Low Tension Glaucoma/pathology , Low Tension Glaucoma/therapy , Intraocular Pressure/physiology , Visual Fields/physiology , Glaucoma, Open-Angle/physiopathology , Glaucoma, Open-Angle/pathology , Glaucoma, Open-Angle/therapy , Risk Factors , Disease Progression , Diagnosis, Differential
6.
Arq. bras. oftalmol ; 71(5): 623-628, set.-out. 2008. ilus, graf, tab
Article in English | LILACS | ID: lil-497210

ABSTRACT

PURPOSE: To evaluate the inflammatory response associated with the use of processed porcine pericardium and glycerin-preserved homologous sclera as silicone glaucoma drainage device coverage in a rabbit experimental model. METHODS: Eight New Zealand white rabbits' eyes received an equal-sized glycerin-preserved homologous scleral patch or a double-layered processed porcine pericardium that was sutured to the bare sclera covering a silicone tube. Conjunctival hyperemia was graded using the double-blind method during the immediate postoperative period and during the first, third, and seventh postoperative weeks. After the seventh week, the enucleated eyes were histopathologically examined. They were also evaluated for signs of patch graft melting, tube erosion and chemosis. RESULTS: There was no occurrence of graft melting or tube exposure, although porcine pericardium was associated with greater inflammation through clinical observation. Light microscopy revealed marked inflammation surrounding the porcine pericardium with foreign body granuloma formation. On the other hand, the sclera group presented milder inflammation with foreign body granulomas only around the sutures. CONCLUSIONS: Porcine pericardium is associated with significant inflammation when used as tube coverage in a rabbit model, at both histopathologic and clinical levels, when compared to glycerin-preserved homologous sclera during the seven-week follow-up period.


OBJETIVO: Avaliar a resposta inflamatória associada com o uso de pericárdio suíno processado e esclera homóloga preservada em glicerina no recobrimento de tubo de drenagem de silicone utilizado em cirurgia de glaucoma em modelo experimental. MÉTODOS: Oito olhos de 8 coelhos albinos da raça Nova Zelândia receberam enxertos do mesmo tamanho de esclera homóloga, preservada em glicerina ou pericárdio suíno processado, suturados à esclera recobrindo um tubo de silicone. Os olhos foram avaliados quanto à hiperemia conjuntival de modo mascarado na primeira, terceira e sétima semanas de pós-operatório. Após a sétima semana os olhos foram enucleados e submetidos a estudo histopatológico. Os olhos também foram avaliados quanto à presença de afinamento do enxerto, exposição do tubo e quemose. RESULTADOS: Não ocorreram casos de afinamento do enxerto ou exposição do tubo, porém o pericárdio suíno esteve associado clinicamente a uma maior inflamação. Achados à microscopia óptica incluíram intensa reação inflamatória em torno do enxerto de pericárdio com formação de granuloma do tipo corpo estranho. Por outro lado, no grupo que recebeu esclera, ocorreu formação de granulomas apenas em torno dos fios de sutura. CONCLUSÃO: O pericárdio suíno esteve associado a maior inflamação tanto à histopatologia quanto clinicamente, quando usado no recobrimento de tubo de silicone, em comparação à esclera homóloga preservada em glicerina, durante o período de acompanhamento de sete semanas.


Subject(s)
Animals , Rabbits , Glaucoma Drainage Implants , Glaucoma/surgery , Pericardium/transplantation , Sclera/transplantation , Foreign-Body Reaction/pathology , Hyperemia/pathology , Pericardium/pathology , Swine , Sclera/pathology , Time Factors
7.
Arq. bras. oftalmol ; 68(4): 565-575, jul.-ago. 2005. ilus
Article in Portuguese | LILACS | ID: lil-417804

ABSTRACT

O glaucoma de pressão normal é neuropatia óptica caracterizada por diminuição da camada de fibras nervosas da retina, aumento da relação escavação/disco e defeito de campo visual, porém sem evidência de aumento da pressão intra-ocular. Os pacientes com glaucoma de pressão normal constituem um grupo heterogêneo em que várias condições sistêmicas podem ser encontradas e apresentam sinais clínicos oculares somente facilmente identificados nos estágios muito avançados da doença. E seu tratamento apresenta desafios maiores do que os existentes no tratamento dos glaucomas hipertensivos. O presente texto propõe uma revisão da patogênese e do diagnóstico diferencial, discutindo os aspectos vasculares, reumáticos, neurológicos e genéticos que devem ser investigados, assim como do tratamento dessa doença. Os autores pesquisaram os bancos de dados do PubMed (MEDLINE), LILACS e Cochrane Library (CENTRAL).


Subject(s)
Humans , Glaucoma/diagnosis , Diagnosis, Differential , Diagnostic Techniques, Ophthalmological , Glaucoma, Open-Angle/diagnosis , Glaucoma, Open-Angle/physiopathology , Glaucoma, Open-Angle/therapy , Glaucoma/physiopathology , Glaucoma/therapy , Intraocular Pressure
8.
Rev. bras. oftalmol ; 63(4): 223-229, abr. 2004. tab, graf
Article in Portuguese | LILACS | ID: lil-398685

ABSTRACT

Objetivo: Analisar os resultados do implante de Susanna em glaucomas em relação a acuidade visual, pressão intra-ocular (Po), número de medicações antiglaucomatosas, complicações e reintervenções cirúrgicas. Local: Departamento de Oftalmologia da Universidade Federal de São Paulo. Métodos: estudo retrospectivo envolvendo 78 olhos (78 pacientes) portadores de glaucoma que foram submetidos a implante de Molteno modificado por Susanna. Foram analisadas a acuidade visual, Po, número de medicações utilizadas no período pré e pós-operatórios, complicações e reintervenções cirúrgicas. Os tipos de glaucoma mais freqüentes submetidos à cirurgia foram o glaucoma neovascular, secundário a cirugia ocular, glaucoma primário de ângulo aberto com falência de cirurgia filtrante prévia, glaucoma secundário a trauma e secundário à uveíte. A cirurgia foi considerada sucesso quando a Po pós-operatória foi menor ou igual a 21mmHg com ou sem medicação e maior que 6mmHg. Resultados: A Po pré-operatória média foi de 26, 5 +- 10, 7 mmHg. No primeiro mês de pós-operatório a Po foi de 17, 2 +- 6, 4 mmHg, no sexto mês de 16, 5 +- 7, 4mmHg e no décimo segundo mês de 15, 4 +- 17, 4mmHg. Houve uma redução estatisticamente significante entre a Po pré e pós-operatória (p= 0, 0001). As porcentagens médias de redução da Po do primeiro, sexto, décimo segundo mês pós-operatório em relação ao pré-operatório foram, respectivamente, de 23, 7 por cento, 28, 9 por cento e 25, 6 por cento. O tempo médio de seguimento foi de 11, 5 +- 7, 8 meses (1-35 meses). A proporção acumulada de sobrevida foi de 64, 2 por cento com 12 meses de pós-opératório. Houve uma diminuição da acuidade visual estatisticamente significante entre os períodos pré-operatório e décimo segundo mês pós-operatório (p= 0, 0013). Houve uma redução estatisticamente significante entre os períodos pré e pós-operatórios (p< 0, 0002) em relação ao número de medicações utilizadas. Complicações ocorreram em 39 olhos (50 por cento). Conclusões: A cirurgia de implante de tubo de Susanna é uma boa alternativa no tratamento de pacientes com glaucoma.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Glaucoma , Glaucoma Drainage Implants , Intraocular Pressure , Glaucoma , Visual Acuity
9.
São Paulo; s.n; 2004. [136] p.
Thesis in Portuguese | LILACS | ID: lil-419368

ABSTRACT

Objetivo: Avaliar prospectivamente as alterações anatõmicas e funcionais decorrentes da trabeculectomia, através da perimetria automatizada acromática, da perimetria de freqüência duplicada, da medida da espessura da camada de fibras nervosas da retina e da topografia da cabeça do nervo óptico. Métodos: Vinte e cinco olhos (25 pacientes) com glaucoma primário de ângulo aberto foram avaliados prospectivamente através de: acuidade visual, pressão intra-ocular, perimetria automatizada acromática, perimetria de freqüência duplicada, analisador das fibras nervosas (GDx) e oftalmoscopia confocal com varredura a laser (Heidelberg Retina Tomograph II), num período de 1 a 2 semanas antes e de 3 a 6 meses após a trabeculectomia. Resultados: A média da idade foi 61 (±14,02; amplitude, 24-86) anos. Foram avaliados 10 homens e 15 mulheres. A acuidade visual (IogMAR) média no pré e pós-operatório foi de 0,28 (±0,18) e 0,30 (±0,17), respectivamente. Num período pós-operatório médio de 4,5 (t1,1; amplitude, 3-6) meses, a Po média pré-operatória de 20,7 (±5,4) mmHg foi reduzida para 11,0 (±2,5) mmHg (p < 0,001). Na biomicroscopia, nenhum dos pacientes apresentou edema retiniano ou de disco óptico decorrentes de hipotonia. O Mean Deviation médio da perimetria acromática foi -11.52 (±8.36) dB e -10.83 (±7.62) dB no pré e pós-operatório, respectivamente. Comparando-se os valores pré e pós-operatórios da perimetria automatizada acromática, perimetria de freqüência duplicada, analisador das fibras nervosas (GDx) e oftalmoscopia confocal com varredura a laser (Heidelberg Retina Tomograph II) não foram encontradas alterações estatisticamente significantes (p ≥ 0,161). Quando se averiguou associação entre possíveis alterações em cada parâmetro e a alteração absoluta e porcentual da Po, também não foram demonstradas correlações com significância estatística (p ≥ 0,296). Conclusão: Os resultados da perimetria automatizada acromática e de freqüência duplicada, do analisador das fibras nervosas (GDx) e da oftalmoscopia confocal com varredura a laser (Heidelberg Retina Tomograph II) não mostraram alterações anatõmicas e funcionais significantes, num período pós-operatório médio de 4,5 meses da trabeculectomia


Subject(s)
Glaucoma , Nerve Fibers , Optic Disk , Trabeculectomy , Visual Fields
10.
Arq. bras. oftalmol ; 66(6): 835-838, nov.-dez. 2003. tab, graf
Article in Portuguese | LILACS | ID: lil-360349

ABSTRACT

OBJETIVOS: Avaliar a influência da utilização do colírio anestésico, bem como verificar o comportamento da medida da pressão intra-ocular (Po) com a adaptação (aprendizado) do paciente à tonometria de não-contato (TNC). MATERIAIS E MÉTODOS: Estudo clínico randomizado duplo-mascarado em que se avaliaram 24 olhos de 24 voluntários normais, sem experiência prévia com a TNC, divididos em 2 grupos: grupo I (TNC com instilação prévia de colírio anestésico seguido de tonometria de aplanação de Goldmann (TAG)) e grupo II (TNC com instilação prévia de colírio placebo seguido de TAG). As medidas da Po foram realizadas em três visitas com intervalo de um a três dias aproximadamente no mesmo horário. RESULTADOS: Constatou-se a Po por meio da TAG como a única variável preditora estatisticamente significante (p < 0,05) para a TNC. Não houve diferença na variação da Po entre os grupos (p = 0,884), tampouco entre as visitas (p = 0,144). Houve melhor correlação entre a TNC e TAG no grupo II em relação ao grupo I em todas as visitas, porém esta diferença não se mostrou estatisticamente significante (p = 0,4853). CONCLUSÕES: A utilização de anestésico tópico e a adaptação de indivíduos normais ao exame de tonometria de não-contato não demonstraram influência significante sobre a medida da Po obtida por este método.


Subject(s)
Humans , Male , Female , Adult , Anesthetics , Intraocular Pressure , Ophthalmic Solutions
11.
Rev. bras. oftalmol ; 58(1): 57-62, jan. 1999. tab
Article in Portuguese | LILACS | ID: lil-246907

ABSTRACT

Desenvolveu-se um estudo caso controle em que se analisaram a microbiota conjuntival e a contaminante dos estojos para lentes de contato (LC) de 40 usuários assintomáticos de LC. Foram utilizados swabs para colher material do fundo de saco conjuntival e dos estojos das lentes. Observou-se contaminaçäo das conjuntivas em 30 por cento dos indivíduos, sendo que 73,9 por cento ocorreram em usuários de LC gelatinosas. Os microorganismos mais encontrados foram os estafilococos coagulase-negativos (60 por cento). Nos estojos, houve alteraçäo da microbiota em 50 por cento das amostras, sendo que a Serratia esteve presente em 70 por cento (60 por cento das lentes duras). Correlaçäo entre a contaminaçäo dos estojos e das conjuntivas foi constatada em um único caso. Encontraram-se fungos em dois estojos (5 por cento). A maioria (65 por cento) dos estojos contaminados pertenciam ao grupo controle (näo estudantes de Medicina). Constatou-se menor contaminaçäo, quantitativa e qualitativa, entre os estudantes de Medicina; e a necessidade de uma melhor orientaçäo sobre a limpeza e desinfecçäo das LC


Subject(s)
Humans , Female , Male , Adult , Conjunctivitis, Allergic/diagnosis , Contact Lenses , Students, Medical
SELECTION OF CITATIONS
SEARCH DETAIL